Laboratory Ultrasonic Engine Cleaner ABS SUS304 Material 6L 45/65kHz Low Noise

Brand Name GT SONIC
Model Number GT SONIC-L6
MOQ 1 pc
Price Negotiable
Packaging Details standard packing : PE Foam + Carton Packing
Payment Terms Western Union, T/T, D/P, D/A, L/C
GT SONIC L6 6L Ultrasonic Cleaner Applications
Laboratory Glassware Cleaning

Laboratory Glassware Cleaning

Narrow-necked flasks, reusable glass vessels and laboratory containers can retain residue in places that are difficult to reach during manual washing. Ultrasonic treatment helps loosen deposits from wetted surfaces, making it useful as part of routine glassware maintenance.

Routine glassware care
Liquid Degassing for Sample Preparation

Liquid Degassing for Sample Preparation

Air introduced during the preparation or transfer of laboratory liquids may remain suspended or dissolved. The L6 includes an extended Degas function of up to 60 minutes, making liquid preparation a distinct application beyond ordinary equipment cleaning.

Degas up to 60 min
Biochemistry and Sample Processing

Biochemistry and Sample Processing

Biochemical laboratory work may involve dispersing materials, mixing liquid samples or investigating ultrasonic treatment as part of an experimental procedure. Three defined power levels and programmable settings provide a basis for evaluating different treatment conditions.

Programmable treatment
Microbiology and Research Laboratory Work

Microbiology and Research Laboratory Work

Research laboratories often carry out different sample-handling procedures throughout the day. The programmable controls and memory function are particularly relevant where established settings need to be used again.

Repeatable procedures
Precision Laboratory Instrument Maintenance

Precision Laboratory Instrument Maintenance

Removable stainless steel holders, instrument fittings and measuring accessories may accumulate handling residue around joints and small openings. A laboratory ultrasonic bath provides an alternative to extensive manual brushing.

Accessory cleaning
Light Industrial and Non-Ferrous Components

Light Industrial and Non-Ferrous Components

Laboratory and workshop cleaning sometimes extends to small brass fittings, steel components, plastic accessories and other manufactured parts. Its configurable ultrasonic output makes it possible to establish different cleaning conditions for robust components and more finish-sensitive materials.

Configurable cleaning
GT SONIC L6 Ultrasonic Cleaner Performance & Features

45kHz, 65kHz and Combined-Frequency

Frequency selection is a distinguishing feature of the L series, with 45kHz, 65kHz and 45kHz & 65kHz configurations for different cleaning requirements.

Different Cavitation Characteristics

A 45kHz setting may be considered for general-purpose work, while 65kHz offers an alternative for suitable items with finer surface details or more sensitive cleaning requirements.

Multiple Frequency Configurations

The series documentation also identifies a combined 45kHz & 65kHz configuration; the exact switching or combined-operation arrangement depends on the supplied model specification.

Three-Level Adjustable Ultrasonic Power

With 150W rated ultrasonic output, the L6 provides defined power levels rather than requiring every procedure to run at maximum intensity.

40%, 70% and 100% Power Settings

Operators can select one of three settings to match the intended cleaning or laboratory treatment.

More Controlled Treatment Conditions

For procedures involving fragile glassware or sensitive accessories, reduced power can be evaluated before increasing ultrasonic intensity.

Extended Degas Function and Low Noise

The L series includes a dedicated degassing capability and a low-noise design suited to shared laboratory environments.

Degassing Periods up to 60 Minutes

The published maximum degassing period allows an extended treatment interval when preparing compatible liquids.

Manufacturer-Stated Noise Below 60dB

GT SONIC specifies an operating noise level below 60dB for the L series, a useful reference for laboratories comparing equipment intended for shared working environments.

Programmable LCD Control and Heating

A programmable interface and integrated heating let laboratory personnel work with defined operating settings.

LCD Display and Memory Function

The control system combines an LCD display with one-button operation and a memory function for repeat-use settings; it also supports multiple languages and Celsius/Fahrenheit display.

300W Heating with Safety Shut-Off

The published temperature range is 0-65C (32-149F) with a 1-60-minute timer and an automatic safety switch-off at 90C.

GT SONIC L6 Ultrasonic Cleaner Specifications
Tank Capacity
6L
Materials
ABS, SUS304 Stainless Steel
Tank Size
300 x 155 x 150mm
Overall Size
400 x 180 x 315mm
Ultrasonic Power
150W
Frequency (L-Series Spec)
45kHz / 65kHz / 45kHz & 65kHz
Power Adjustment
40% / 70% / 100%
Heating Power
300W
Temperature Setting
0-65C / 32-149F
Timer
1-60 Minutes / Untimed
Control and Safety
LCD, Memory, Degas, 90C Safety Shut-Off
Model
Tank Size (mm)
Unit Size (mm)
Capacity (L)
Ultrasonic Power (W)
Heating Power (W)
GT SONIC L3
240 x 140 x 100
320 x 165 x 285
3
100
100
GT SONIC L6
300 x 155 x 150
400 x 180 x 315
6
150
300
GT SONIC L10
300 x 240 x 150
400 x 270 x 315
10
200
300
GT SONIC L30
500 x 300 x 200
605 x 330 x 385
30
500
500

Note - The product's general Detail Information lists 40kHz, while the L-series technical specification lists 45kHz / 65kHz / 45kHz & 65kHz. Both values are retained as published; confirm the frequency configuration supplied with the ordered model. L-series operating parameters (power levels, degas up to 60 min, noise below 60dB, 90C safety shut-off) follow the published L-series specification.

How to Use the GT SONIC L6 6L Ultrasonic Cleaner
3-Step Use Guide

Three-Step Use Guide

1. Fill — Fill the 6L SUS304 tank to the appropriate level with water or a detergent approved for the workpiece, and keep the electrical body and controls dry.

2. Place and set — Place parts in the basket without crowding, then set the cleaning mode, temperature and time according to the material and residue.

3. Run and remove — Start the cycle; when it ends, lift out the parts, rinse if needed and dry them, then empty and wipe the tank after use.

What Can It Clean?

What Can It Clean?

Glassware Sample liquids Biochemical samples Research accessories Instrument holders Brass and non-ferrous parts

Suitability depends on the material, coatings, adhesives and the detergent used; check compatibility before immersion.

What to Note?

Operation Tips

Confirm ultrasonic degassing suitability for the liquid and method Reduce power for fragile glassware before increasing intensity Do not treat every sample with the same setting Avoid flammable or volatile solvents in degassing Verify calibrated instruments' cleaning instructions Confirm the memory function behavior after a power interruption
Get Best Price
Frequently Asked Questions About the GT SONIC L6 Ultrasonic Cleaner
How do I choose between a 45kHz and 65kHz ultrasonic cleaner?
expand

A 45kHz configuration may be considered for suitable general laboratory cleaning, while 65kHz offers different cavitation characteristics that may benefit some items with fine surface features. The L-series documentation also describes 45kHz & 65kHz combined-frequency operation. The appropriate choice depends on the workpiece, contamination and intended procedure, as well as the frequency arrangement supplied with the machine.

Can an ultrasonic cleaner with degas be used for sample preparation?
expand

Ultrasonic degassing may be useful when dissolved or entrained gases interfere with later liquid-handling steps. The L6 has a published degassing capability of up to 60 minutes. It can be considered for compatible aqueous preparations, but analytical applications involving HPLC mobile phases or volatile solvents need separate chemical and process evaluation.

Is a low noise ultrasonic cleaner suitable for a shared laboratory?
expand

The L series is specified with an operating noise level below 60dB, making it relevant when equipment noise is an important consideration. Actual suitability depends on the laboratory environment and any applicable acoustic requirements. Where a defined noise limit must be met, the manufacturer's test conditions and measurement method should be reviewed.

Why would a laboratory need three adjustable ultrasonic power levels?
expand

Different workpieces and experimental procedures may respond differently to ultrasonic intensity. The 40%, 70% and 100% settings give users defined options for evaluating treatment conditions, rather than relying on maximum output every time. For delicate materials, cleaning trials help determine whether a reduced setting provides the required result without unwanted surface effects.

Is a 6L laboratory ultrasonic bath large enough for glassware and sample holders?
expand

The L6 tank measures 300 x 155 x 150mm, providing space for appropriately sized glass vessels, holders and reusable accessories. If a laboratory regularly handles wider items, the L10 offers a 300 x 240 x 150mm chamber with additional horizontal space. Capacity selection should take account of workpiece dimensions and the required liquid clearance rather than volume alone.

Can a programmable ultrasonic cleaner retain settings for repeated procedures?
expand

The published L-series features include programmable operation and a memory function. These are useful when the same parameters are required for recurring laboratory work. The available product information does not specify the number of memory positions or the precise behavior following a power interruption, so those details can be clarified when ordering for a procedure that depends on stored settings.

Get a Quote for GT SONIC L6
Related Products
New Condition Ultrasonic Parts Washer Lab Equipment GT SONIC 6L 40kHz 300 Watt

New Condition Ultrasonic Parts Washer Lab Equipment GT SONIC 6L 40kHz 300 Watt

View Details
Laboratory Ultrasonic Parts Cleaner Bath 9L 200W 40KHz Electric Fuel 1 Year Warranty

Laboratory Ultrasonic Parts Cleaner Bath 9L 200W 40KHz Electric Fuel 1 Year Warranty

View Details
40KHz 6L Digital Control Parts Ultrasonic Cleaner , Heated Ultrasonic Washer 150W

40KHz 6L Digital Control Parts Ultrasonic Cleaner , Heated Ultrasonic Washer 150W

View Details
Multi - Frequency Parts Ultrasonic Cleaner Heated Soak Tank 13L 28kHz/40KHz

Multi - Frequency Parts Ultrasonic Cleaner Heated Soak Tank 13L 28kHz/40KHz

View Details
6L Heating Manual Ultrasonic Cleaner Power Adjustable 40kHz 150W 0-30 Mins Timer

6L Heating Manual Ultrasonic Cleaner Power Adjustable 40kHz 150W 0-30 Mins Timer

View Details
Double Power Heated Ultrasonic Parts Cleaner 3L Volume With 0-30 Mins Timer

Double Power Heated Ultrasonic Parts Cleaner 3L Volume With 0-30 Mins Timer

View Details
Titaninum Parts Ultrasonic Cleaner , GT SONIC S3 Ultrasonic Brass Cleaner 220v

Titaninum Parts Ultrasonic Cleaner , GT SONIC S3 Ultrasonic Brass Cleaner 220v

View Details
Contact Now